Lighting plans shall be included in all development involving major building and/or circulation improvements and will be approved on a project-by-project basis. Plans should include the following elements for consideration:

A. A photometric site plan, drawn to scale, showing proposed buildings and/or parking areas, mounting and pole height and including all proposed exterior lighting fixtures and foot-candle spread.

B. Design specifications for all proposed lighting fixtures to include photometric data, cutoff fixtures, bulb wattage/type, and other descriptive information.

C. Outside parking lot lighting shall not be less than one-half foot-candle per IES minimum lighting standards at the property line.

D. Wall packs on buildings may be used at entrances to a building to light unsafe areas. Wall packs are not intended to draw attention to the building or provide general building or site lighting. Wall packs must be fully shielded to direct the light downward.

E. Building and aesthetic lighting must be shielded to prevent direct glare and/or light trespass in excess of one-half foot-candle.

F. Lighting must be, as much as physically possible, designed to minimize glare and spillover into adjacent properties. [Ord. 2017-11-025 § 18 (Exh. I)].